Test Name REF LAB GLUCOSE TOLERANCE GESTATIONAL 3 SPECIMENS (75G)
Orderable CPT 82951
OVT 123051718927
Synonyms QUEST 18927
Result Test Name 1 HOUR SPECIMEN
Laboratory QUEST LAB
Result Test Code 1230512445
Laboratory Test Name Glucose Tolerance Test Gestational 3 Specimens (75g)
Reportable Test Name -
Result LOINC 1507-3
Collection Container K OXALATE AND NA FLUORIDE - GREY TOP
Units -
Collection Requirements Preferred Specimen(s) Three - 1 mL plasma specimens collected in fluoride/oxalate (gray-top) tubes Alternative Specimen(s) Plasma from fluoride/oxalate (gray-top) tube in a plastic screw-cap vial ? Serum (separated from cells immediately) in a plastic screw-cap vial ? Spun SST ? Plasma from lithium heparin (green-top) tube in a plastic screw-cap vial ? Plasma from sodium heparin (green-top) tube in a plastic screw-cap vial Minimum Volume 0.5 mL for each specimen Collection Instructions Immediately after a fasting specimen is obtained have patient ingest a 75 g load of glucose. Draw subsequent specimens 1 and 2 hours later. Label each with the specific draw time. Serum and plasma submissions must be separated from cells. Transport Container Fluoride/oxalate (gray-top) tubes Transport Temperature Room temperature
Container Temp Room Temperature (1)
Container Volume .500
Test Info -
Shipping Instructions -
Result Test Name FASTING SPECIMEN
Laboratory QUEST LAB
Result Test Code 3595
Laboratory Test Name Glucose Tolerance Test Gestational 3 Specimens (75g)
Reportable Test Name -
Result LOINC 1558-6
Collection Container K OXALATE AND NA FLUORIDE - GREY TOP
Units -
Collection Requirements Preferred Specimen(s) Three - 1 mL plasma specimens collected in fluoride/oxalate (gray-top) tubes Alternative Specimen(s) Plasma from fluoride/oxalate (gray-top) tube in a plastic screw-cap vial ? Serum (separated from cells immediately) in a plastic screw-cap vial ? Spun SST ? Plasma from lithium heparin (green-top) tube in a plastic screw-cap vial ? Plasma from sodium heparin (green-top) tube in a plastic screw-cap vial Minimum Volume 0.5 mL for each specimen Collection Instructions Immediately after a fasting specimen is obtained have patient ingest a 75 g load of glucose. Draw subsequent specimens 1 and 2 hours later. Label each with the specific draw time. Serum and plasma submissions must be separated from cells. Transport Container Fluoride/oxalate (gray-top) tubes Transport Temperature Room temperature
Container Temp Room Temperature (1)
Container Volume .500
Test Info -
Shipping Instructions -
Result Test Name 2 HOUR SPECIMEN
Laboratory QUEST LAB
Result Test Code 3596
Laboratory Test Name Glucose Tolerance Test Gestational 3 Specimens (75g)
Reportable Test Name -
Result LOINC 1558-6
Collection Container K OXALATE AND NA FLUORIDE - GREY TOP
Units -
Collection Requirements Preferred Specimen(s) Three - 1 mL plasma specimens collected in fluoride/oxalate (gray-top) tubes Alternative Specimen(s) Plasma from fluoride/oxalate (gray-top) tube in a plastic screw-cap vial ? Serum (separated from cells immediately) in a plastic screw-cap vial ? Spun SST ? Plasma from lithium heparin (green-top) tube in a plastic screw-cap vial ? Plasma from sodium heparin (green-top) tube in a plastic screw-cap vial Minimum Volume 0.5 mL for each specimen Collection Instructions Immediately after a fasting specimen is obtained have patient ingest a 75 g load of glucose. Draw subsequent specimens 1 and 2 hours later. Label each with the specific draw time. Serum and plasma submissions must be separated from cells. Transport Container Fluoride/oxalate (gray-top) tubes Transport Temperature Room temperature
Container Temp Room Temperature (1)
Container Volume .500
Test Info -
Shipping Instructions -
Result Test Name SEE NOTE
Laboratory QUEST LAB
Result Test Code 3597
Laboratory Test Name Glucose Tolerance Test Gestational 3 Specimens (75g)
Reportable Test Name -
Result LOINC 8251-1
Collection Container K OXALATE AND NA FLUORIDE - GREY TOP
Units -
Collection Requirements Preferred Specimen(s) Three - 1 mL plasma specimens collected in fluoride/oxalate (gray-top) tubes Alternative Specimen(s) Plasma from fluoride/oxalate (gray-top) tube in a plastic screw-cap vial ? Serum (separated from cells immediately) in a plastic screw-cap vial ? Spun SST ? Plasma from lithium heparin (green-top) tube in a plastic screw-cap vial ? Plasma from sodium heparin (green-top) tube in a plastic screw-cap vial Minimum Volume 0.5 mL for each specimen Collection Instructions Immediately after a fasting specimen is obtained have patient ingest a 75 g load of glucose. Draw subsequent specimens 1 and 2 hours later. Label each with the specific draw time. Serum and plasma submissions must be separated from cells. Transport Container Fluoride/oxalate (gray-top) tubes Transport Temperature Room temperature
Container Temp Room Temperature (1)
Container Volume .500
Test Info -
Shipping Instructions -